一、工作原理

配(pei)電(dian)箱是按電(dian)氣接(jie)線要求將(jiang)開關(guan)設備、測量(liang)儀(yi)表、保(bao)護電(dian)器(qi)和輔助(zhu)(zhu)設備組裝在封閉或(huo)半封閉金屬柜中(zhong)或(huo)屏幅上,構成低(di)壓配(pei)電(dian)箱。正(zheng)常運行(xing)時可(ke)借助(zhu)(zhu)手動(dong)或(huo)自動(dong)開關(guan)接(jie)通或(huo)分斷(duan)電(dian)路。故(gu)障或(huo)不正(zheng)常運行(xing)時借助(zhu)(zhu)保(bao)護電(dian)器(qi)切斷(duan)電(dian)路或(huo)報警。借測量(liang)儀(yi)表可(ke)顯示(shi)運行(xing)中(zhong)的各種參數,還可(ke)對(dui)某些(xie)電(dian)氣參數進行(xing)調整,對(dui)偏離正(zheng)常工作(zuo)狀態進行(xing)提示(shi)或(huo)發出信(xin)號。

二、常見故障改進

1.對于配(pei)電(dian)(dian)變壓(ya)器(qi)容(rong)量在(zai)(zai)100kV·A及以上的配(pei)電(dian)(dian)箱體(ti),在(zai)(zai)箱內散(san)熱窗靠側壁處,應考慮到安裝溫(wen)控繼電(dian)(dian)器(qi)(JU-3型(xing)或(huo)JU-4超(chao)小型(xing)溫(wen)度繼電(dian)(dian)器(qi))和(he)軸流(liu)風機,安裝在(zai)(zai)控制(zhi)電(dian)(dian)器(qi)板上方左側面的箱體(ti)上,以便使(shi)箱內溫(wen)度達到一定值(zhi)時(如40℃)能(neng)自動啟動排(pai)氣扇,強行(xing)排(pai)出熱量以使(shi)箱體(ti)散(san)熱。

2.采用保(bao)護電(dian)(dian)路(lu)防止(zhi)配電(dian)(dian)箱(xiang)供電(dian)(dian)的外部電(dian)(dian)路(lu)故障的發(fa)生。選擇體積較(jiao)小的智能(neng)缺(que)相保(bao)護器,如可選用DA88CM-II型電(dian)(dian)機(ji)缺(que)相保(bao)護模塊(kuai)(上海(hai)產品)安(an)裝(zhuang)于配電(dian)(dian)箱(xiang)內以防止(zhi)因低(di)壓(ya)缺(que)相運(yun)行而燒壞(huai)電(dian)(dian)動機(ji)。

3.改進原配(pei)電(dian)箱的低壓(ya)電(dian)容(rong)器(qi)組的接(jie)線方式,將(jiang)其安裝位置(zhi)由交流接(jie)觸器(qi)上(shang)樁頭,改成(cheng)接(jie)在(zai)配(pei)電(dian)箱低壓(ya)進線與計量(liang)表計之間。防止因運(yun)行中(zhong)電(dian)容(rong)器(qi)電(dian)路發生缺相故障或電(dian)容(rong)器(qi)損壞時,造(zao)成(cheng)計量(liang)裝置(zhi)計量(liang)不準確。此外(wai),電(dian)容(rong)器(qi)選(xuan)擇型(xing)號(hao)應為BSMJ系(xi)列產品,以(yi)保(bao)證元(yuan)件質量(liang)可靠、安全(quan)運(yun)行。

4.若新增柱上(shang)配電(dian)臺架,在制作配電(dian)箱外殼時,可(ke)選2mm厚的(de)(de)(de)不銹鋼板材,并適當按比例放大配電(dian)箱尺(chi)寸(在農改(gai)工程(cheng)使用的(de)(de)(de)JP4—100/3W型基礎上(shang),在原箱體(ti)(ti)寬(kuan)度方向尺(chi)寸上(shang)增大約(yue)100mm,即由(you)原680mm改(gai)為780mm。改(gai)進后的(de)(de)(de)配電(dian)箱體(ti)(ti)外形尺(chi)寸為:1300mm×780mm×500mm),以便增加各分(fen)路(lu)出(chu)線之間、出(chu)線與箱體(ti)(ti)外殼的(de)(de)(de)電(dian)氣安全距(ju)離(li),這樣有利于農電(dian)工的(de)(de)(de)操(cao)作維(wei)護和更(geng)換熔件,同時也可(ke)散熱。

5.選(xuan)用節能型(xing)交(jiao)流(liu)接(jie)觸器(qi)(qi)(類似CJ20SI型(xing))產(chan)品(pin),并注意交(jiao)流(liu)接(jie)觸器(qi)(qi)線(xian)(xian)圈(quan)電(dian)壓與所選(xuan)剩作電(dian)流(liu)動作保護(hu)器(qi)(qi)的相對應(ying)接(jie)線(xian)(xian)端子(zi)相連,注意進(jin)行正(zheng)確(que)的負載匹(pi)配。選(xuan)擇交(jiao)流(liu)接(jie)觸器(qi)(qi)時,應(ying)選(xuan)用其絕(jue)緣等級(ji)為A級(ji)及(ji)以(yi)上產(chan)品(pin),必須保證(zheng)其主回路(lu)觸點的額定電(dian)流(liu)應(ying)大于或等于被控制(zhi)的線(xian)(xian)路(lu)的負荷電(dian)流(liu)。接(jie)觸器(qi)(qi)的電(dian)磁線(xian)(xian)圈(quan)額定電(dian)壓為380V或220V。

6.剩(sheng)余(yu)電流動作保護器(qi)(qi)(qi)的(de)(de)選用(yong)。必(bi)須(xu)選用(yong)符合GB 6829《剩(sheng)余(yu)電流動作保護器(qi)(qi)(qi)的(de)(de)一般要(yao)求》標準、并經中(zhong)國(guo)(guo)電工產品(pin)(pin)認(ren)證委員(yuan)會(hui)認(ren)證合格的(de)(de)產品(pin)(pin)。可選用(yong)類(lei)似(si)LJM(J)系列節電型、且是低靈(ling)敏度的(de)(de)延時型保護器(qi)(qi)(qi)。保護器(qi)(qi)(qi)裝置的(de)(de)方式要(yao)符合國(guo)(guo)家(jia)GB13955-2005《剩(sheng)余(yu)電流動作保護裝置的(de)(de)安裝和運行(xing)》標準。漏電保護器(qi)(qi)(qi)的(de)(de)分斷時間(jian),當漏電電流為(wei)額定漏電電流時,其動作時間(jian)不(bu)應大于0.s。

7.配電(dian)(dian)箱(xiang)的進出(chu)線(xian)選用(yong)(yong)(yong)低壓(ya)電(dian)(dian)纜(lan)(lan),電(dian)(dian)纜(lan)(lan)的選擇(ze)應符合技術(shu)要求。例如30kVA、50kVA變(bian)壓(ya)器(qi)的配電(dian)(dian)箱(xiang)的進線(xian)使用(yong)(yong)(yong)VV22-35×4電(dian)(dian)纜(lan)(lan),分(fen)路(lu)出(chu)線(xian)使用(yong)(yong)(yong)同(tong)規(gui)格的VLV22-35×4電(dian)(dian)纜(lan)(lan);80kVA、100kVA變(bian)壓(ya)器(qi)的配電(dian)(dian)箱(xiang)的進線(xian)分(fen)別使用(yong)(yong)(yong)VV22-50×4、VV22-70×4電(dian)(dian)纜(lan)(lan),分(fen)路(lu)出(chu)線(xian)分(fen)別使用(yong)(yong)(yong)VLV22-50×4、VLV22-70×4電(dian)(dian)纜(lan)(lan),其電(dian)(dian)纜(lan)(lan)與銅鋁(lv)接(jie)(jie)(jie)線(xian)鼻壓(ya)接(jie)(jie)(jie)后再用(yong)(yong)(yong)螺栓與配電(dian)(dian)箱(xiang)內接(jie)(jie)(jie)線(xian)樁頭(tou)連(lian)接(jie)(jie)(jie)。

8.熔(rong)(rong)(rong)(rong)斷(duan)器(qi)(qi)(qi)(RT、NT型)的(de)(de)選用。配電(dian)(dian)(dian)(dian)變壓(ya)器(qi)(qi)(qi)的(de)(de)低壓(ya)側(ce)總過(guo)流(liu)(liu)保(bao)護熔(rong)(rong)(rong)(rong)斷(duan)器(qi)(qi)(qi)的(de)(de)額(e)(e)(e)(e)定(ding)(ding)電(dian)(dian)(dian)(dian)流(liu)(liu),應(ying)大于(yu)配電(dian)(dian)(dian)(dian)變壓(ya)器(qi)(qi)(qi)的(de)(de)低壓(ya)側(ce)額(e)(e)(e)(e)定(ding)(ding)電(dian)(dian)(dian)(dian)流(liu)(liu),一般取額(e)(e)(e)(e)定(ding)(ding)電(dian)(dian)(dian)(dian)流(liu)(liu)的(de)(de)1.5倍(bei),熔(rong)(rong)(rong)(rong)體(ti)的(de)(de)額(e)(e)(e)(e)定(ding)(ding)電(dian)(dian)(dian)(dian)流(liu)(liu)應(ying)按變壓(ya)器(qi)(qi)(qi)允許的(de)(de)過(guo)負荷倍(bei)數和熔(rong)(rong)(rong)(rong)斷(duan)器(qi)(qi)(qi)特性確定(ding)(ding)。出線回(hui)路(lu)過(guo)流(liu)(liu)保(bao)護熔(rong)(rong)(rong)(rong)斷(duan)器(qi)(qi)(qi)的(de)(de)熔(rong)(rong)(rong)(rong)體(ti)額(e)(e)(e)(e)定(ding)(ding)電(dian)(dian)(dian)(dian)流(liu)(liu),不(bu)應(ying)大于(yu)總過(guo)流(liu)(liu)保(bao)護熔(rong)(rong)(rong)(rong)斷(duan)器(qi)(qi)(qi)的(de)(de)額(e)(e)(e)(e)定(ding)(ding)電(dian)(dian)(dian)(dian)流(liu)(liu),熔(rong)(rong)(rong)(rong)體(ti)的(de)(de)額(e)(e)(e)(e)定(ding)(ding)電(dian)(dian)(dian)(dian)流(liu)(liu)按回(hui)路(lu)正常最大負荷電(dian)(dian)(dian)(dian)流(liu)(liu)選擇,并應(ying)躲過(guo)正常的(de)(de)尖峰(feng)電(dian)(dian)(dian)(dian)流(liu)(liu)。

9.為了對農村低壓電網無功功率進行分析,在箱內安裝一只DTS(X)系(xi)列的有功、無功二合一多功能(neng)電能(neng)表(安裝在計(ji)量(liang)表計(ji)板(ban)側),用于更換原安裝的三(san)只單相電能(neng)表(DD862系(xi)列表計(ji)),以便于對負荷的在線運(yun)行監(jian)測。

三、注意事項

(1)施(shi)工用(yong)電(dian)配(pei)電(dian)系統應設置(zhi)總配(pei)電(dian)箱、分配(pei)電(dian)箱、開(kai)關箱,并按照(zhao)“總-分-開(kai)”順序作分級(ji)設置(zhi),并形成“三級(ji)配(pei)電(dian)”模式。

(2)施(shi)工用(yong)配(pei)(pei)電(dian)系統(tong)各配(pei)(pei)電(dian)箱(xiang)(xiang)、開關箱(xiang)(xiang)的(de)安(an)裝位(wei)置(zhi)要合理。總配(pei)(pei)電(dian)箱(xiang)(xiang)要盡量靠近變壓器或外(wai)電(dian)源處,以便電(dian)源的(de)引(yin)入。分(fen)配(pei)(pei)電(dian)箱(xiang)(xiang)應盡量安(an)裝在用(yong)電(dian)設備或負(fu)荷(he)相對集(ji)中的(de)中心地帶,確保(bao)三相負(fu)荷(he)保(bao)持(chi)平衡。開關箱(xiang)(xiang)安(an)裝的(de)位(wei)置(zhi)應視現場情況和工況盡量靠近其控(kong)制(zhi)的(de)用(yong)電(dian)設備。

(3)保證臨時用電(dian)配(pei)電(dian)系統三相(xiang)負荷平衡,施工現場(chang)的動(dong)力用電(dian)和照明用電(dian)應形成兩(liang)個用電(dian)回路,動(dong)力配(pei)電(dian)箱(xiang)與照明配(pei)電(dian)箱(xiang)應該分別設置。

(4)施工現場所有用電設備必須有各自(zi)的(de)專用的(de)開(kai)關箱。

(5)各級(ji)配電(dian)箱(xiang)的箱(xiang)體和(he)內部(bu)設置(zhi)必須(xu)符合(he)安全(quan)規定,開關電(dian)器應(ying)標(biao)明用途,箱(xiang)體應(ying)統一編(bian)號。停止(zhi)使用的配電(dian)箱(xiang)應(ying)切斷電(dian)源(yuan),箱(xiang)門上鎖。固定式配電(dian)箱(xiang)應(ying)設置(zhi)圍(wei)欄(lan),并有(you)防雨防砸措(cuo)施。

(6)配(pei)(pei)電箱與配(pei)(pei)電柜的區別。根據GB/T20641-2006《低(di)壓成套開關設備和(he)控(kong)制(zhi)設備空殼體(ti)的一(yi)般要求》

配電(dian)箱(xiang)一般是(shi)家(jia)庭用(yong)的,而配電(dian)柜(ju)則多用(yong)在集中供電(dian)中,比(bi)如說(shuo)工業用(yong)電(dian)和建筑(zhu)用(yong)電(dian)等(deng),配電(dian)箱(xiang)和配電(dian)柜(ju)都屬(shu)于(yu)成(cheng)套設(she)備,配電(dian)箱(xiang)屬(shu)于(yu)低壓成(cheng)套設(she)備,配電(dian)柜(ju)有(you)高壓有(you)低壓。

(圖文(wen)來源:網(wang)絡(luo),版權(quan)歸原作(zuo)者所有,若有侵權(quan)請聯(lian)系刪除)