變壓器該如何養護?遵從什么法則?

閱讀次數:750    發布時間: 2021-05-07 16:55:48

變(bian)(bian)(bian)壓(ya)器(qi)(qi)(qi)是(shi)變(bian)(bian)(bian)換(huan)交流(liu)電(dian)(dian)(dian)壓(ya)、電(dian)(dian)(dian)流(liu)和(he)(he)阻(zu)(zu)抗(kang)的(de)器(qi)(qi)(qi)件,變(bian)(bian)(bian)壓(ya)器(qi)(qi)(qi)工作原理是(shi)利(li)用(yong)電(dian)(dian)(dian)磁感應原理制成的(de)靜止用(yong)電(dian)(dian)(dian)器(qi)(qi)(qi)。它的(de)分類有很多,按照不(bu)通用(yong)的(de)作用(yong)可分為脈沖(chong)功(gong)率變(bian)(bian)(bian)壓(ya)器(qi)(qi)(qi)、中(zhong)周變(bian)(bian)(bian)壓(ya)器(qi)(qi)(qi)、觸發(fa)變(bian)(bian)(bian)壓(ya)器(qi)(qi)(qi)、屏蔽變(bian)(bian)(bian)壓(ya)器(qi)(qi)(qi)等(deng)等(deng)。變(bian)(bian)(bian)壓(ya)器(qi)(qi)(qi)利(li)用(yong)電(dian)(dian)(dian)磁感應原理,從一(yi)個電(dian)(dian)(dian)路(lu)向另一(yi)個電(dian)(dian)(dian)路(lu)傳(chuan)遞電(dian)(dian)(dian)能(neng)或傳(chuan)輸(shu)信號的(de)一(yi)種(zhong)電(dian)(dian)(dian)器(qi)(qi)(qi),是(shi)電(dian)(dian)(dian)能(neng)傳(chuan)遞或作為信號傳(chuan)輸(shu)的(de)重(zhong)要元件。變(bian)(bian)(bian)壓(ya)器(qi)(qi)(qi)是(shi)變(bian)(bian)(bian)換(huan)交流(liu)電(dian)(dian)(dian)壓(ya)、電(dian)(dian)(dian)流(liu)和(he)(he)阻(zu)(zu)抗(kang)的(de)器(qi)(qi)(qi)件,當初級(ji)線(xian)(xian)圈中(zhong)通有交流(liu)電(dian)(dian)(dian)流(liu)時,鐵(tie)芯(或磁芯)中(zhong)便(bian)產生交流(liu)磁通,使次級(ji)線(xian)(xian)圈中(zhong)感應出電(dian)(dian)(dian)壓(ya)(或電(dian)(dian)(dian)流(liu))。變(bian)(bian)(bian)壓(ya)器(qi)(qi)(qi)由鐵(tie)芯(或磁芯)和(he)(he)線(xian)(xian)圈組成,線(xian)(xian)圈有兩個或兩個以上(shang)的(de)繞(rao)組,其中(zhong)接電(dian)(dian)(dian)源的(de)繞(rao)組叫初級(ji)線(xian)(xian)圈,其余(yu)的(de)繞(rao)組叫次級(ji)線(xian)(xian)圈。

那么,變壓器該如何保養?遵循以下5大保養法則即可:

 

一、允許溫度

變(bian)(bian)壓(ya)(ya)器運行時,它的線圈和鐵(tie)(tie)芯產生(sheng)銅損(sun)和鐵(tie)(tie)損(sun),這些損(sun)耗變(bian)(bian)為熱(re)能,使(shi) 變(bian)(bian)壓(ya)(ya)器的鐵(tie)(tie)芯和線圈溫(wen)度上升。若溫(wen)度長時間超過允許值會使(shi)絕緣漸漸失(shi)去機(ji) 械(xie)彈性(xing)而使(shi)絕緣老化。

變壓器運行時各部分的溫度是不相同的,線圈的溫度高,其次是鐵芯的 溫度,絕緣油溫度低于線圈和鐵芯的溫度。變壓器的上部油溫高于下部油溫。變壓器運行中的允許溫度按上層油溫來檢查。對于 A 級絕緣的變壓器在正常運 行中,當周圍空氣溫度高為 400C 時,變壓器繞組的極限工作溫度是 1050C。由于繞組的溫度比油溫度高 100C,為防止油質劣化,規定變壓器上層油溫高 不超過 950C,而在正常情況下,為防止絕緣油過速氧化,上層油溫不應超過 850C。對于采用強迫油循環水冷卻和風冷的變壓器,上層油溫不宜經常超過 750C。(這種變壓器上層油溫最大允許值為 800C)

 

二、允許溫升

 

只監視變壓(ya)(ya)器(qi)(qi)運(yun)(yun)(yun)行中的(de)上(shang)層油(you)溫(wen),還不(bu)能保證變壓(ya)(ya)器(qi)(qi)的(de)安(an)全(quan)運(yun)(yun)(yun)行,還須(xu) 監視上(shang)層油(you)溫(wen)與冷卻空氣(qi)的(de)溫(wen)差—即溫(wen)升(sheng)(sheng)。變壓(ya)(ya)器(qi)(qi)溫(wen)度與周(zhou)圍(wei)空氣(qi)溫(wen)度的(de)差值, 稱為變壓(ya)(ya)器(qi)(qi)的(de)溫(wen)升(sheng)(sheng)。對 A 級(ji)絕緣的(de)變壓(ya)(ya)器(qi)(qi),當周(zhou)圍(wei)最高溫(wen)度為 400C 時,國家(jia) 標準規定(ding)繞組的(de)溫(wen)升(sheng)(sheng) 650C, 上(shang)層油(you)溫(wen)的(de)允(yun)許溫(wen)升(sheng)(sheng)為550C。只要(yao)變壓(ya)(ya)器(qi)(qi)溫(wen)升(sheng)(sheng)不(bu)超過規定(ding)值, 就能保證變壓(ya)(ya)器(qi)(qi)在額定(ding)負荷下規定(ding)的(de)運(yun)(yun)(yun)行年限內安(an)全(quan)運(yun)(yun)(yun)行。(變壓(ya)(ya)器(qi)(qi)在正常運(yun)(yun)(yun)行時帶額定(ding)負荷可連續運(yun)(yun)(yun)行 20 年)

 

三、合理容量

 

在正(zheng)常(chang)運行(xing)時(shi),應(ying)使(shi)變壓(ya)器(qi)承受的用電負荷在變壓(ya)器(qi)額(e)定(ding)容量的 75—90% 左右。

 

四、合理電流范圍

 

變壓器低壓最(zui)大(da)不平衡電(dian)流不得超過額定(ding)(ding)值的 25%;變壓器電(dian)源(yuan)電(dian)壓變 化允(yun)許范圍為額定(ding)(ding)電(dian)壓的正負 5%。

 

如果超過這(zhe)一(yi)范圍(wei)應(ying)(ying)采用(yong)分(fen)接(jie)(jie)開(kai)關進行調(diao)整, 使電壓(ya)(ya)(ya)達到規定范圍(wei)。(調(diao)整 時應(ying)(ying)停電進行)通常是改變(bian)(bian)(bian)一(yi)次繞組分(fen)接(jie)(jie)抽頭的(de)(de)位(wei)置(zhi)實現調(diao)壓(ya)(ya)(ya)的(de)(de),連接(jie)(jie)及(ji)切換 分(fen)接(jie)(jie)抽頭位(wei)置(zhi)的(de)(de)裝置(zhi)叫分(fen)接(jie)(jie)開(kai)關,它(ta)是通過改變(bian)(bian)(bian)變(bian)(bian)(bian)壓(ya)(ya)(ya)器高壓(ya)(ya)(ya)繞組的(de)(de)匝數來調(diao)整 變(bian)(bian)(bian)比(bi)的(de)(de)。電壓(ya)(ya)(ya)低(di)對(dui)變(bian)(bian)(bian)壓(ya)(ya)(ya)器本身無影(ying)響,只降低(di)一(yi)些出力,但對(dui)用(yong)電設(she)備有影(ying)響; 電壓(ya)(ya)(ya)增(zeng)高,磁通增(zeng)加(jia)(jia),鐵(tie)芯飽和,鐵(tie)芯損耗增(zeng)加(jia)(jia),變(bian)(bian)(bian)壓(ya)(ya)(ya)器溫度(du)升高。

 

五、過負荷

 

過(guo)(guo)(guo)(guo)負(fu)(fu)(fu)荷(he)(he)分正常(chang)過(guo)(guo)(guo)(guo)負(fu)(fu)(fu)荷(he)(he)和事故過(guo)(guo)(guo)(guo)負(fu)(fu)(fu)荷(he)(he)兩種情況(kuang)。正常(chang)過(guo)(guo)(guo)(guo)負(fu)(fu)(fu)荷(he)(he)是在正常(chang)供電(dian)情況(kuang)下,用(yong)戶(hu)用(yong)電(dian)量增(zeng)加而引起(qi)的。它將使變(bian)(bian)(bian)壓(ya)(ya)器(qi)溫度升高,導致(zhi)變(bian)(bian)(bian)壓(ya)(ya)器(qi)絕緣加 速老化,使用(yong)壽命降(jiang)低,因(yin)此一般情況(kuang)下不(bu)允許(xu)過(guo)(guo)(guo)(guo)負(fu)(fu)(fu)荷(he)(he)運行(xing)。特殊情況(kuang)變(bian)(bian)(bian)壓(ya)(ya)器(qi) 可在短時間內過(guo)(guo)(guo)(guo)負(fu)(fu)(fu)荷(he)(he)運行(xing),但在冬(dong)季不(bu)得超過(guo)(guo)(guo)(guo)額定負(fu)(fu)(fu)荷(he)(he) 30%,夏季不(bu)得超過(guo)(guo)(guo)(guo)額 定負(fu)(fu)(fu)荷(he)(he)的 15%。此外,應根據變(bian)(bian)(bian)壓(ya)(ya)器(qi)的溫升與制造廠規定來確定變(bian)(bian)(bian)壓(ya)(ya)器(qi)的過(guo)(guo)(guo)(guo)負(fu)(fu)(fu) 荷(he)(he)能力。

 

當(dang)電力系(xi)統(tong)或用戶變(bian)電站發生事(shi)(shi)故(gu)(gu)時(shi),為保證對(dui)重要設備的(de)連續供(gong)電,故(gu)(gu) 允(yun)許(xu)變(bian)壓(ya)器(qi)(qi)短時(shi)間過(guo)(guo)(guo)負(fu)(fu)荷運(yun)行(xing),即事(shi)(shi)故(gu)(gu)過(guo)(guo)(guo)負(fu)(fu)荷,事(shi)(shi)故(gu)(gu)過(guo)(guo)(guo)負(fu)(fu)荷時(shi)會引起(qi)線圈溫度(du) 超過(guo)(guo)(guo)允(yun)許(xu)值,因此對(dui)絕(jue)緣來講比正常條(tiao)件老化要快。但事(shi)(shi)故(gu)(gu)過(guo)(guo)(guo)負(fu)(fu)荷的(de)機會少, 在一(yi)般(ban)情況下(xia)(xia)變(bian)壓(ya)器(qi)(qi)又是(shi)欠負(fu)(fu)荷運(yun)行(xing),所以(yi)短時(shi)的(de)過(guo)(guo)(guo)負(fu)(fu)荷致于損壞變(bian)壓(ya)器(qi)(qi)的(de)絕(jue) 緣。事(shi)(shi)故(gu)(gu)過(guo)(guo)(guo)負(fu)(fu)荷的(de)時(shi)間及倍(bei)數應根據制造廠規定執行(xing),如沒廠家(jia)資(zi)料也可參照(zhao) 如下(xia)(xia)數值。

 

自(zi)然冷卻油浸式變壓器允許的(de)事故過負荷倍數及時間

干式變壓器事(shi)故過負荷(he)倍數及時間(用于(yu)室內)

類型:開啟式、封閉式、澆注式。

 

這種(zhong)變壓器用(yong)于(yu)(yu)安全防火較高的場合,開啟式是常用(yong)的型(xing)式,其器身與大氣相 通,適于(yu)(yu)比(bi)較干燥而潔凈的室內(nei)環境。涂裝、車體變電所變壓器就屬于(yu)(yu)此種(zhong)。

 

六、問答:變壓器在運行中溫度升高的原因是什么?

 

分為外因(yin)和(he)內因(yin)兩種情況。

 

外因:超時間的過負荷或冷卻通(tong)風不好。

 

內因:

①變(bian)壓(ya)(ya)器鐵(tie)芯(xin)硅片(pian)之間的(de)絕(jue)緣(yuan)損(sun)壞,使變(bian)壓(ya)(ya)器的(de)空載損(sun)耗增加, 變(bian)壓(ya)(ya)器溫(wen)度升高。

②變壓(ya)器繞組的絕(jue)緣損(sun)壞造成(cheng)匝間短(duan)路,產(chan)生電弧而(er)發熱,使 變壓(ya)器溫(wen)度升高。

③分接開關接觸(chu)不良,接觸(chu)電阻(zu)增大而發熱(re),使變(bian)壓器(qi)溫度升 高。

④套管(guan)內外部接(jie)(jie)線(xian)接(jie)(jie)觸不良。

 

(來源(yuan):網(wang)絡,版權歸原(yuan)作(zuo)者)